● Using patented state-of-the-art non-dispersive infrared(NDIR)wave-guide technology and offers reliable measurements
● Comply to EMC directive 2014 / 30 / EU
● CO2 Measuring range:0 … 2,000 / 0 … 5,000 / 0 … 10,000 / 0 … 20,000(PPM) (Max.:50,000 PPM);IP65 / IP54
● Digital output(RS-485 Modbus RTU protocol, 0 ... 6000 PPM), analog output(0 … 10 V, 4 … 20 mA)
● Maintenance-free in most HVAC ventilation applications
● High tolerance to extreme humidity environment conditions
● Non-frill design, direct DDC connection
eyc-tech GS07 is a state-of-the-art non-dispersive infrared(NDIR)carbon dioxide(CO2 )transmitter. The
direct insertion design and miniature size make it easy to install in the ventilation duct.
eyc-tech GS07 provides measurement in analog outputs(0 … 10 V, 4 … 20 mA)and digital output(RS-485
Modbus RTU protocol).
With CO2 demand controlled ventilations, eyc-tech GS07 helps to save money by decreasing the energy
consumption while maintaining a healthier indoor climate
CO2 Measuring range
|
0 … 2,000 / 0 … 5,000 / 0 … 10,000 / 0 … 20,000 (PPM)
(Max. : 50,000 PPM)
|
Output
|
RS-485
|
Digital output with Modbus RTU protocol
|
Voltage signal terminal CO2 Note 3
|
Voltage or current output : Jumper
selection(Default 0 … 10 V)
D/A resolution : 10 bits(10 mV / 0.016 mA)
D/A conversion accuracy : ±2% of reading±50 mV
Electrical characteristics : Voltage output-ROUT<100 Ω, RLOAD>5 kΩ
Current output-RLOAD<500 Ω
|
Operating temperature range
|
0 … 50°C
|
Storage temperature range
|
-40 … +70°C
|
Operating humidity range
|
0 … 100% RH(Sensor in powered-up condition)
|
Operating environment
|
Residential, commercial and industrial spacesNote 1
|
Warm-up time
|
≦1 min(at full specs≦15 min)
|
Sensor life expectancy
|
>15 years
|
Duct air velocity
|
Direct insertion sensor, no minimum airs peed requirement
|
Maintenance interval
|
No maintenance Note 2(with ABC algorithm)
|
Power input
|
AC / DC 24 V±20%, 50 Hz or 60Hz(Half-wave rectifier input)
|
Power consumption
|
<1 W average
|
Connection wires
|
M12 male connector for power input (G+, G0) & voltage/current output (Out)
with M12 female quick connection cable (AWG24 wires)
|
Sensing method
|
Non-dispersive
infrared(NDIR)wave-guide technology with
Automatic Background Calibration(ABC)and passive gas diffusion(No moving
parts)
|
Response time(T1/e)
|
<10 sec(at 30 cc/min flow rate)/ <3 min diffusion time
|
Repeatability
|
±30 PPM±1% of reading
|
Accuracy at 25°C Note 1,2
|
±40 PPM±3% of reading (2000/5000
PPM), ±200 PPM±3% of reading (10000/20000 PPM)
|
Annual zero drift Note 1,2
|
<±10 PPM(with ABC function)
|
Pressure dependence
|
+1.6% reading per hPa
|
Installation support
|
Background level calibration adjustment jumper trigger(bCAL)
|
Dimension
|
94x30 mm diameter
|
Duct probe length
|
51 mm
|
IP rating
|
IP65
|
Compliance with EMC directive
|
2014 / 30 / EU
|
Note 1: The SO
2 enriched environments are excluded.
Note 2: In normal IAQ applications(at NTP). Accuracy is defined after minimum 3 weeks of continuous operation. The tolerance of the span calibration gas (2% unless otherwise requested)and test gas adds to the total uncertainty.
Note 3: The specifications are valid for the output load connected to ground G0. Other outputs and measurement ranges are available per request.
Greenhouses / Mushroom farming / Industrial safety / AHUs in high RH regions