Technology
|
|
Standard
|
IEEE 802.3 10Base-T Ethernet
|
|
|
IEEE 802.3u 100Base-TX Fast Ethernet
|
|
|
IEEE 802.3ab 1000Base-T Gigabit Ethernet copper
|
|
|
IEEE 802.3z Gigabit Ethernet Fiber
|
|
|
IEEE 802.3x Flow Control and back-pressure
|
|
|
IEEE 802.1AB Link Layer Discovery Protocol(LLDP)
|
|
|
IEEE 802.1p Class of Service (CoS)
|
|
|
IEEE 802.1QVLAN and GVRP
|
|
|
ITU-T G.8032 Ethernet ring protection switching(ERPS)
|
|
|
IEEE 802.1D-2004 Rapid Spanning Tree Protocol(RSTP)
|
|
|
IEEE 802.1Q-2005 Multiple Spanning Tree Protocol(MSTP)
|
|
|
IEEE 802.3ad Link Aggregation Control Protocol(LACP)
|
|
|
IEEE 802.1xPort based Network Access Protocol
|
|
|
IEEE 1588Precision Time Protocol v1/v2
|
|
Performance
|
|
Switch Technology
|
Store and Forward Technology with Non-Blocking Switch Fabric
|
|
Number of MAC Address
|
16K
|
|
Packet Buffer Memory
|
1.5M Bytes
|
|
Jumbo Frame
|
9216 Bytes
|
|
Transfer performance
|
10Base-T: 14,880pps, 100Base-TX: 148,800pps, 1000Base-TX/FX: 1,488,100pps
|
|
VLAN
|
256VLANs
|
|
VLAN ID
|
1~4094
|
|
Class of Service
|
8 Priority Queues per Port
|
|
Watchdog
|
Hardware-based 10 seconds timer
|
|
Interface
|
|
Ethernet Port
|
8 x 10/100/1000BaseT RJ-45, Auto-Negotiation
4 x 100/1000Base SFP, DDM
|
|
System LED
|
2 x Power: Green On
1 x System Status: Ready:Green On, Fireware Updating:Green Blinking
1 x DO: Red On
1 x DI: Green On
1 x Ring: Off: Ring disabled, Green On: Ring normal (Not RPL Owner),Green Blinking: Ring normal (RPL Owner), Amber On: Ring abnormal, Amber Blinking:Ring port fail
|
|
Ethernet Port LED
|
Link (Green On), Activity (Green Blinking), Speed 1000M(Amber On), Speed 100M(Off)
|
|
SFP LED
|
Link (Green On), Activity (Green Blinking), Speed 1000M(Amber On), Speed 100M(Off)
|
|
Rsest
|
System Reboot(2-6 Seconds)/Default Settings Reset (over 7 Seconds)
|
|
Console
|
1 x RS232 in RJ45 for System Configuration. Baud Rate: 115200.n.8.1
|
|
USB
|
1 x USB for Configuration/Firmware Update
|
|
Power Input, Digital Intput, Digital Output
|
8-Pin Removable Terminal Block Connector
4 Pin for Redundant Power
4 Pin for DI,DO( Relay Alarm)
1 x Digital Output: Dry Relay Output with 0.5A /24V DC
1 x Digital Input: DI with Photo-Coupler Isolation
High: DC 11V~30V
Low: DC 0V~10V
|
|
Power Requirement
|
|
Input Voltage
|
24VDC(10~60VDC)
|
|
Reverse Polarity Protect
|
Yes
|
|
Input Current
|
0.67A@24V
|
|
Power Consumption
|
Max 16.08W@24VDC full traffic, suggest to reserve 15% tolerance
|
|
Software
|
|
Management Interface
|
CGI WebGUI, Command Line Interface (CLI), Telnet, SNMP
|
|
Time Management
|
NTP,IEEE 1588 Precision Time Protocol v1/v2
|
|
Network Management
|
IPv4/IPv6, SNMP v1/v2c/v3/Trap, MIBs, RMON, LLDP, DHCP
server/client/Option 82, TFTP, System Log, SMTP
|
|
Traffic Management
|
Flow Control, Port Trunk/802.3ad LACP, VLAN, Private VLAN, GVRP, GMRP, QinQ, QoS, IGMP Snooping v1/v2/v3, Rate Control, Storm Control, Port Mirror
|
|
Security
|
IEEE 802.1X/RADIUS, Private VLAN, ACL(MAC/IP filter), HTTPs/SSH secure login, SFTP*DHCP Snooping, IP Source Guard, Dynamic ARP Inspection, 802.1XMAB, TACACS+
|
|
Redundancy
|
Rapid Spanning Tree Protocol (RSTP)/Multiple Spanning Tree Protocol (MSTP)
ITU-T G.8032 v1/v2 Ethernet Ring Protection Switching (ERPS)
|
|
Mechanical
|
|
Installation
|
DIN Rail
|
|
Enclosure Material
|
Steel Metal with Aluminum
|
|
Dimension
|
85.5(W) x 150(H) x 126.5(D) mm / without DIN Rail Clip
|
|
Ingress Protection
|
IP31
|
|
Weight
|
1.38KG
|
|
Environmental
|
|
Operating Temperature & Humidity
|
-40°C~75°C , 0%~95% Non-Condensing
|
|
Storage Temperature
|
-40°C~85°C
|
|
Hi-Pot Insulation
|
AC1.5KV
|
|
MTBF
|
>500,000 hours
|
|
Warranty
|
5 years
|
|
Standard
|
|
Safety
|
IEC60950-1 Compliance
|
|
EMC
|
EN61000-6-2/EN61000-6-4
|
|
EMI
|
CISPR 22, FCC part 15B Class A
|
|
EMS
|
EN61000-4-2 ESD: 8KV(Air), 6KV(Contact)
EN61000-4-3 RS: 20V/m(80M~1GHz), 10V/m(1.4G~2.1GHz), 5V/m(2.1G~2.5GHz)
EN61000-4-4 EFT: 2KV (Power, Signal Port, GND)
EN61000-4-5 Surge: Power 2KV/1KV(Line to Ground/Line to Line), Siganal Port: 2KV(Line to Ground)
EN61000-4-6 CS: 10 Vms(Power, Signal Port)
EN61000-4-8 Magnetic Field: 30A/m continues/300A for1~3s
|
|
Railway
|
EN50121-4
|
|
Substation
|
EN 61850-3/ IEEE1613
|