ES100 is an intergraded device and designed for all types of environmental monitoring. It can be used to detect multiple parameters of temperature, humidity, PM2.5, PM10, wind speed and wind direction in the environment. Each parameter is independent and high sensitivity, users can freely integrate monitoring parameters. ES100 has the characteristics of high precision and good stability, which is suitable for various environmental monitoring. The ES100 is equipped with a standard RS485 interface and supports the Modbus RTU protocol, which can be integrated into the Internet of Things and cloud interfaces, such as smart city boxes and wireless routers, for real-time monitoring and analysis via remote smartphones or computers.
|
Specifications
|
|
ES106 System Parameter
|
|
Power Input
|
12 / 24VDC (12~24VDC)
|
|
Communication
|
RS485 Modbus-RTU
|
|
Op.temp.&Humidity
|
-40°C~80°C, 15~95%RH 无凝结
|
|
Warranty
|
1 year
|
|
ES106 Interface
|
|
RS485
|
2 wires
Pin Define: Yellow (Gray): RS485+; Blue: RS485-
|
|
Power Input
|
2 wires
Pin Define: Brown : V+; Black: V-
|
|
ES106 Inspection Parameter
|
|
Wind Speed
|
Detection Range
|
0~60m/s
|
|
Accuracy Level
|
±1m/s
|
|
Operation Temperature
|
-40~80℃
|
|
Operation Humidity
|
15-95%RH
|
|
Wind Direction
|
Detection Range
|
0~360° (16方位)
|
|
Accuracy Level
|
1 Direction
|
|
Operation Temperature
|
-40~80℃
|
|
Operation Humidity
|
15-95%RH
|
|
Temperature
|
Detection Range
|
-40~80℃
|
|
Accuracy Level
|
±0.5℃
|
|
Humidity
|
Detection Range
|
0~100%RH
|
|
Accuracy Level
|
±3%RH
|
|
PM2.5
|
Detection Range
|
0-1000ug/m³
|
|
Measurement
|
Laser Detection
|
|
Accuracy Level
|
<±10% (25℃)
|
|
Resolution
|
0.1ug/m³
|
|
Operation Temperature
|
-40~80℃
|
|
Operation Humidity
|
0-95%RH
|
|
PM10
|
Detection Range
|
0-1000ug/m³
|
|
Measurement
|
Laser Detection
|
|
Accuracy Level
|
<±10% (25℃)
|
|
Resolution
|
0.3ug/m³
|
|
Operation Temperature
|
-40~80℃
|
|
Operation Humidity
|
0-95%RH
|
|
ES104 Inspection Parameter
|
|
Temperature
|
Detection Range
|
-40~80℃
|
|
Accuracy Level
|
±0.5℃
|
|
Humidity
|
Detection Range
|
0~100%RH
|
|
Accuracy Level
|
±3%RH
|
|
PM2.5
|
Detection Range
|
0-1000ug/m³
|
|
Measurement
|
Laser Detection
|
|
Accuracy Level
|
<±10% (25℃)
|
|
Resolution
|
0.1ug/m³
|
|
Operation Temperature
|
-40~80℃
|
|
Operation Humidity
|
0-95%RH
|
|
PM10
|
Detection Range
|
0-1000ug/m³
|
|
Measurement
|
Laser Detection
|
|
Accuracy Level
|
<±10% (25℃)
|
|
Resolution
|
0.3ug/m³
|
|
Operation Temperature
|
-40~80℃
|
|
Operation Humidity
|
0-95%RH
|
|
ES102 Inspection Parameter
|
|
Wind Speed
|
Detection Range
|
0~60m/s
|
|
Accuracy Level
|
±1m/s
|
|
Operation Temperature
|
-40~80℃
|
|
Operation Humidity
|
15-95%RH
|
|
Wind Direction
|
Detection Range
|
0~360° (16 Directions)
|
|
Accuracy Level
|
1 Direction
|
|
Operation Temperature
|
-40~80℃
|
|
Operation Humidity
|
15-95%RH
|
|
Communication Protocol Basic Parameter
|
|
Protocol
|
Modbus-RTU
|
|
Data bits
|
8 bit
|
|
Parity bit
|
No
|
|
Stop bit
|
1
|
|
Error Detecting Code
|
CRC
|
|
Baude Rate
|
2400bps/4800bps/9600bps, default setting is 9600bps
|
|
Device Stack List
|
|
ModBus ID
|
Parameter
|
Decimal
|
Address
|
Description
|
|
40001
|
Humidity
|
1
|
3
|
Range:0~100.0%RH
|
|
40002
|
Temperature
|
1
|
3
|
Range:-40~80℃
|
|
40005
|
PM2.5
|
0
|
3
|
Range:0~1000ug/m3
|
|
40010
|
PM10
|
0
|
3
|
Range:0~1000ug/m3
|
|
40257
|
Device Address
|
0
|
|
Device Address
|
|
40258
|
Bard Rate
|
0
|
|
0 =2400, 1 =4800, 2 =9600
|
|
40023
|
Wind Speed
|
1
|
1
|
Range:0-60m/s
|
|
40024
|
Wind Direction
|
0
|
2
|
North-NortEast: 0x0000 NorthEast: 0x0001
NorthEast - East: 0x0002 East: 0x0003
East-East: 0x0004 SouthEast: 0x0005
South - SouthEast: 0x0006 South: 0x0007
South - SouthWest: 0x0008 SouthWest: 0x0009
West-West: 0x000A West: 0x000B
West - NorthWest: 0x000C NorthWest: 0x000D
North - NorthWest: 0x000E North: 0x000F
|
Intergraded Device
-
Intergraded multiple sensorsCentral management by sharing a signal output
-
Support Industrial Modbus RTU protocol, RS485
Outdoor Protective Enclosure
-
Prevent direct ultraviolet radiation to the sensors
-
Avoid rapid aging of sensors under harsh environmental conditions such as strong winds, rain, and snow
-
The sensor parts are ventilated for truly sensing the changes in external detection parameters
Flexible Design
-
Customized Shutter Height: Single or multiple parameters both can use small shutter, small size, light weight and easy to install
-
Customized Monitoring parameters: Each parameter is independent and high sensitivity, users can freely integrate monitoring parameters
Work with IoT Cloud Platform - ThingsMaster
-
Real-time online monitoring, analysis, reporting
-
Remote cloud security and visual management
|
Ordering Information
|
|
Model
|
|
ES106
|
Outdoor Environment Air Quality Inspection System. Integrated embedded Hum., Temp., PM2.5, PM10 sensors, and external Wind Direction, Wind Speed sensors, Output: RS485
|
|
|
Package List
|
|
|
1 x Shutter
|
|
|
1 x Wind Direction Sensor (including cable)
|
|
|
1 x Wind Speed Sensor (including cable)
|
|
|
1 x QIG
|
|
Model
|
|
ES104
|
Outdoor Environment Air Quality Inspection System. Integrated embedded Hum., Temp., PM2.5, PM10 sensors, Output: RS485
|
|
|
Package List
|
|
|
1 x Shutter
|
|
|
1 x QIG
|
|
Model
|
|
ES102
|
Outdoor Environment Air Quality Inspection System. Integrated external Wind Direction, Wind Speed sensors, Output: RS485
|
|
|
Package List
|
|
|
1 x Wind Direction Sensor (including cable)
|
|
|
1 x Wind Speed Sensor (including cable)
|
|
|
1 x QIG
|