Measurement
Ranges:
(23°C ±5°C, 80% R.H. MAX) Accuracy:±(%rdg+dgt)
Measurement
|
Range
|
Resolution
|
Accuracy
|
Input Resistance
|
Remarks
|
DE-11
|
(ACV)
|
4V
|
0.001V
|
2.3%+10
|
approx. 11MΩ
|
*Accuracy in the case of sine
wave.
*Frequency range 40~500Hz
|
40V
|
0.01V
|
approx. 10MΩ
|
400V
|
0.1V
|
2.3%+5
|
600V
|
1V
|
(DCV)
|
400mV
|
0.1mV
|
0.7%+3
|
≥100MΩ
|
────
|
4V
|
0.001V
|
1.3%+3
|
approx. 11MΩ
|
40V
|
0.01V
|
approx. 10MΩ
|
400V
|
0.1V
|
600V
|
1V
|
(Resistance)
|
400Ω
|
0.1Ω
|
2%+5
|
────
|
*Openvoltage:approx.0.4V
*The measuring current changes in accordance with the
resistance measured.
|
4kΩ
|
0.001kΩ
|
40kΩ
|
0.01kΩ
|
400kΩ
|
0.1kΩ
|
4MΩ
|
0.001MΩ
|
5%+5
|
40MΩ
|
0.01MΩ
|
10%+5
|
(DIODE)
|
4V
|
0.001V
|
10%+5
|
────
|
Open voltage:Approx.1.5V
|
(BUZZER)
|
400Ω
|
0.1Ω
|
────
|
────
|
*Buzzer
turns on less than 60±20Ω
*Open
voltage:Approx.
0.4V
|
(CAP)
|
4nF
|
0.001nF
|
5%+25
|
────
|
Accuracy
is subject to zero set by pressing relative key before forwarding
measurement.
|
40nF
|
0.01 nF
|
5%+10
|
400nF
|
0.1nF
|
4μF
|
0.001μF
|
40μF
|
0.01μF
|
10%+15
|
200μF
|
0.1μF
|
Hz
|
9.999Hz
|
0.001Hz
|
0.7%+5
|
────
|
*Accuracy in
the case of sine wave.
9.999Hz~9.999kHz:10Vrms
min
99.99kHz:40Vrms
min
|
99.99Hz
|
0.01Hz
|
999.9Hz
|
0.1Hz
|
9.999kHz
|
0.001kHz
|
99.99kHz
|
0.01kHz
|
DUTY
|
0.1~99%
|
0.1%
|
────
|
────
|
*About input
sensitivity and frequency characteristic:
(Square wave
DUTY 50% input) 2.5V 0 to peak input:≧1kHz
6V 0 to peak
input:≧10kHz
40V 0
to peak input:≧70kHz
|
TEMP./Humidity:
-
Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no
condensation)
-
Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no
condensation)
Dimension
& Weight:
-
110(L)x56(W)x11.5(H)mm
-
Approx.99.3
(Including Battery & Leather Case)
Accessories:
-
Instruction
Manual x 1
-
CR2032
Li-ion Cell (installed) x1
-
Test
Lead (black + red attached with Meter) x 1
-
Leather
Case x1