Measurement
Ranges:
23°C
± 5°C max. 80%R.H. Accuracy: ±(%rdg
+dgt)
Measurement
|
Range
|
Resolution
|
Accuracy
(Responding Hz)
|
Input
Impedance
|
Max.
Input Voltage
|
DE-5200(sine
wave)
|
DE-5202 / 5203
|
ACV
|
2.2000V
|
0.0001V
|
0.7%+15(40Hz~1kHz)
|
*0.7%+40(40Hz~1kHz)
|
Approx. 11MΩ
|
1000V rms
|
22.000V
|
0.001V
|
0.7%+10(40Hz~1kHz)
|
*0.8%+40 (40Hz~1kHz)
*1.5%+40(1kHz~5kHz)
|
Approx. 10MΩ
|
220.00V
|
0.01V
|
1000.0V
|
0.1V
|
1.0%+10(40Hz~1kHz)
|
*1.0%+40(40Hz~2kHz)
|
*True RMS value: applicable to 10%~100% of the
range
Measurement
|
Range
|
Resolution
|
Accuracy
|
Input
Impedance
|
Max.
Input Voltage
|
DCV
|
2.2000V
|
0.0001V
|
0.1%+5
|
Approx. 11MΩ
|
1000V rms
|
22.000V
|
0.001V
|
Approx. 10MΩ
|
220.00V
|
0.01V
|
1000.0V
|
0.1V
|
0.3%+5
|
Measurement
|
Range
|
Resolution
|
Accuracy
|
Input
Impedance
|
Max.
Input Voltage
|
DCmV
|
220.00mV
|
0.01mV
|
0.1%+5
|
≧100MΩ
|
1000V rms
|
Measurement
|
Range
|
Resolution
|
Accuracy
(Responding Hz)
|
Input
Impedance
|
Max.
Input Voltage
|
DE-5200(sine
wave)
|
DE-5202 / 5203
|
ACmV
|
220.00mV
|
0.01mV
|
0.5%+15(40Hz~1kHz)
1.2%+20(1Hz~2kHz)
|
*0.5%+30(40Hz~1kHz)
*1.2%+30(1Hz~10kHz)
|
≧100MΩ
|
1000V rms
|
*True RMS value: applicable to 10%~100% of the
range
Measurement
|
Range
|
Resolution
|
Accuracy
|
Overload
Protection
|
Ω
Resistance
|
220.00 Ω
|
0.01Ω
|
0.5%+5
|
1000V rms
|
2.2000kΩ
|
0.0001kΩ
|
22.000kΩ
|
0.001kΩ
|
220.00kΩ
|
0.01kΩ
|
2.2000MΩ
|
0.0001MΩ
|
22.000MΩ
|
0.001MΩ
|
1.0%+10
|
220.0MΩ
|
0.1MΩ
|
5.0%+10
|
Measurement
|
Range
|
Resolution
|
Remarks
|
Open-loop Voltage
|
Overload
Protection
|
Continuity
|
220.00Ω
|
0.01Ω
|
Buzzer emits at
around ≦30Ω
|
-3.0V
|
1000V rms
|
Measurement
|
Range
|
Resolution
|
Accuracy
|
Open-loop Voltage
|
Overload
Protection
|
Diode
|
2.2000V
|
0.0001V
|
0.5%+5
|
>2.5V
|
1000V rms
|
Measurement
|
Range
|
Resolution
|
Accuracy
|
Open-loop
Voltage
|
Overload Protection
|
Capacitance
|
22.000nF
|
0.001nF
|
1.5%+20
|
At 22nF/220nF ranges
Press “REL” to offset the
reading before measurement
|
1000V rms
|
220.00nF
|
0.01nF
|
2.2000μF
|
0.0001μF
|
2.0%+20
|
22.000μF
|
0.001μF
|
220.00μF
|
0.01μF
|
2.2000mF
|
0.0001mF
|
2.0%+20
|
22.000mF
|
0.001mF
|
220.00mF
|
0.01mF
|
6.0%+20
|
Measurement
|
Range
|
Resolution
|
Accuracy
|
Remarks
|
Overload Protection
|
Hz
&
Duty***
|
22.00Hz*
|
0.01Hz
|
0.1%+5
|
* valid>2.00Hz
** valid > 20.0Hz
***Duty:5%~94.9% (<10kHz3Vp-p) resolution: 0.1%.
Display: UL(<5.0%)
OL (>94.9%)
|
1000V rms
|
220.0Hz**
|
0.1Hz
|
22.000kHz
|
0.001kHz
|
220.00kHz
|
0.01kHz
|
Measurement
|
Range
|
Resolution
|
Accuracy
(Responding Hz)
|
Overload
Protection
|
DE-5200(sine wave)
|
*DE-5202 / 5203
|
250mA/ 1000V
fuse
|
AC
|
μA
|
220.00μA
|
0.01μA
|
0.8%+10(40Hz~1kHz)
1.5%+10(1kHz~2kHz)
|
*0.8%+30(40Hz~1kHz)
*1.5%+30(1kHz~10kHz)
|
2200.0μA
|
0.1μA
|
mA
|
22.000mA
|
0.001mA
|
220.00mA
|
0.01mA
|
**A
|
**10.000A
|
0.001A
|
1.8%+20(40Hz~1kHz)
2.0%+20(1kHz~2kHz)
|
*1.5%+30(40Hz~1kHz)
*2.0%+40(1kHz~10kHz)
|
10A/1000V
fuse
|
*True RMS value: applicable to 10% to 100% of the
range.
**over range 11 ~ 20A stands with 30 sec. max.
Measurement
|
Range
|
Resolution
|
Accuracy
|
Overload
Protection
|
DC
|
μA
|
220.00μA
|
0.01μA
|
0.5%+5
|
250mA/ 1000V
fuse
|
2200.0μA
|
0.1μA
|
mA
|
22.000mA
|
0.001mA
|
220.00mA
|
0.01mA
|
0.8%+5
|
A
|
*10.000A
|
0.001A
|
1.2%+10
|
10A/1000V
fuse
|
over range 11 ~ 20A stands with 30 sec. max.
Measurement
|
Range
|
Resolution
|
Accuracy
|
DE-5200/5202
|
DE-5203
|
°C
°F
|
-40.0℃~
1000.0℃
-40.0℉~
1830.0℉
|
0.1℃
0.1℉
|
——
|
-40.0℃ ~ 400.0℃
|
1.0% +4℃
|
-40.0℉ ~ 752.0℉
|
1.0% +8℉
|
400.1℃ ~ 1000.0℃
|
1.5% +10℃
|
752.1℉ ~ 1830.0℉
|
1.5% +18℉
|
Measurement
|
Range
|
Accuracy
|
Remarks
|
Peak
Hold*
|
DCV, ACV
|
3.0%+50
|
* pulse width≧100uS
valid≧2000 counts
|
DCmV, ACmV
|
DCμA, ACμA
|
ACmA, DCmA
|
DCA, ACA
|
Temperature coefficient: 0.1 x
(specified accuracy) / ℃ (<18℃ or >28℃)
TEMP./Humidity:
-
Operation:0°C~ 50°C(32℉~122℉)/<80%
R.H.(no condensation)
-
Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no
condensation)
Dimension & Weight:
-
181(L)x91(W)x57(H)mm
-
Approx.400g
(Excluding battery)
Accessories:
-
Battery AA 1.5V
x 2
-
Instruction
Manual x 1
-
Test Lead (red +
black) x 1