1. Introduction:
A capacitor after winding, heat stabilizing and end spraying often be a short circuit. Clearing is achieved by applying a voltage across the capacitor so that sufficient current can flow to clear the short without allowing too much to flow and so damage the end connection.
2. Feature:
(1) Automatic loading and unloading, easy to operate and adjust, finishing whole procedure in only one process.
(2) Process control system is by PLC system.
(3) Counting function for the no-good short elements.
(4) The machine will not stop running when the no-good element was rejected at the first step.
(5) Saving time by simultaneously multi-stage voltage operation.
(6) Counting and classification function for the good and no-good elements of high voltage test.
(7) Positive and negative charge up to DC 0~3000V, the voltage, speed and time could be adjusted.
(8) DC high voltage short test DC 0~3000V 10mA, the voltage, speed and time could be adjusted.
(9) Low voltage which can clear short circuit, high voltage with DC voltage, and voltage started from zero stage which can clear short circuit.
(10) Without destruction of electric character, dissipation factor would not change after finishing operation.
Electrication:
1. Power source: 220V 50/60hz 1ψ2w 3kva.
2. Air pressure: 5kg/cm2.
3. Output:
(1) Pulse clearing AC 50V/2A.
(2) Short alarm DC 24V/2A.
(3) Hi-voltage clearing DC 0~2500V/10ma.
Cycle time: 1~5 seconds (adjustable).
4. Machine dimensions: W1600 x D950 x H1750 mm.
5. Machine weight: about 500 kgs.
Mechanical:
1. Element size in machine:
(1) H: 8 ~ 17 mm.
(2) T: 2.5 ~ 12 mm.
(3) W: 10 ~ 32 mm.
2. Element size in part feeder:
(1) H: 8 ~ 17 mm.
(2) T: 2.5 ~ 12 mm.
(3) W: 10 ~ 32 mm.
3. Part feeding methods:
(1) Round: part feeder flat-part feeder.
(2) Horizontal: DC motor with belt, speed adjustable.
4. Indexing methods:
Cylinder and indexing gear.